Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit Page
y97
Communication Data
Storage Selection
0: Store into nonvolatile mem-
ory (Rewritable times are limit-
ed)
1: Write into temporary memo-
ry (Rewritable times are unlim-
ited)
2: Save all data from tempora-
ry memory to nonvolatile
memory (After all data is
saved, return to Data 1)
1
Availa-
ble
-
page
8-5
y99
Support T
ool Link
Function Selection
0: Numerical setting and termi-
nal command (including oper-
ation command ) by related
parameter settings
1: Numerical setting uses
communications command
(support tools)
2: Terminal setting uses com-
munications command (sup-
port tools)
3: Both numerical setting and
terminal command use com-
munications command (sup-
port tools)
Numerical setting means Fre-
quency reference, torque com-
mand, or torque bias com-
mand.
0
Availa-
ble
-
-
4-2-12
Parameter S (Via RS-485)
These parameters are exclusively for reading and writing via the RS-485 interface. These parameters
are not displayed on the Digital Operator
. To check these parameters, use Sysmac Studio.
Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit Page
S01 Frequency Reference
-32,768 to 32,767
+20,000 or -20,000 = Maxi-
mum output frequency
0
Availa-
ble
-
page
5-27
4 Parameter List
4-161
M1 Series Standard Type User's Manual (I669)
4-2 List of Parameters by Group
4
4-2-12 Parameter S (Via RS-485)