Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit Page
F52
Braking Resistor Re-
sistance
0.01 to 999 Ω
0.01
Availa-
ble
ohm
page
5-75
F58
Output Terminal [AO]
Filter
0.00 to 5.00 s
0.00
Availa-
ble
s
page
7-46
F59
Output Terminal [AO]
Bias
-100.0 to 100.0 %
0.0
Availa-
ble
%
page
7-46
F80 Load Mode Selection
0: HHD
1: HND
3: HD (only for 400 V)
4: ND (only for 400 V)
0 - -
page
5-12
4-2-2
Parameter E (Terminal Functions)
Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit Page
E01
Input Terminal [DI1]
Function Selection
0 to 188 normally-open input,
1000 to 1188 normally-close
input
0 -
-
page
7-26
E02
Input Terminal [DI2]
Function Selection
0 to 188 normally-open input,
1000 to 1188 normally-close
input
1 -
-
page
7-26
E03
Input Terminal [DI3]
Function Selection
0 to 188 normally-open input,
1000 to 1188 normally-close
input
2 - -
page
7-26
E04
Input Terminal [DI4]
Function Selection
0 to 188 normally-open input,
1000 to 1188 normally-close
input
7 -
-
page
7-26
4 Parameter List
4-84
M1 Series Standard Type User's Manual (I669)