EasyManuals Logo
Home>Omron>Inverter>M1 Series

Omron M1 Series User Manual

Omron M1 Series
808 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #346 background imageLoading...
Page #346 background image
When Drive Control Selection (F42) = 15, 16 (synchronous motor)
The set values of the following parameters are overwritten with the following values according to
the new settings after changing Load Mode Selection (F80).
Manual Torque Boost V
oltage (F09)
Power supply Model
Capacity
[kW]
Manual Torque Boost Voltage (F09)
Set value
Load Mode Selection (F80)
0: HHD 1: HND 3: HD 4: ND
Three-phase 200 V
3G3M1-A2001 0.1 8.4 6.7 - -
3G3M1-A2002 0.2 8.4 6.7 - -
3G3M1-A2004 0.4 7.1 4.0 - -
3G3M1-A2007 0.75 6.8 3.5 - -
3G3M1-A2015 1.5 6.8 4.9 - -
3G3M1-A2022 2.2 6.8 4.5 - -
3G3M1-A2037 3.7 5.5 4.1 - -
3G3M1-A2055 5.5 4.9 3.4 - -
3G3M1-A2075 7.5 4.4 2.7 - -
3G3M1-A2110 11 3.5 2.1 - -
3G3M1-A2150 15 2.8 1.6 - -
3G3M1-A2185 18.5 2.2 1.3 - -
Three-phase 400 V
3G3M1-A4004 0.4 7.1 4.0 7.1 4.0
3G3M1-A4007 0.75 6.8 3.5 6.8 3.5
3G3M1-A4015 1.5 6.8 4.9 6.8 4.9
3G3M1-A4022 2.2 6.8 4.5 6.8 4.5
3G3M1-A4030 3.0 6.8 4.5 6.8 4.5
3G3M1-A4040 4.0 5.5 4.1 5.5 4.1
3G3M1-A4055 5.5 4.9 3.4 4.9 3.4
3G3M1-A4075 7.5 4.4 2.7 4.4 2.7
3G3M1-A4110 11 3.5 2.1 3.5 2.1
3G3M1-A4150 15 2.8 1.6 2.8 1.6
3G3M1-A4185 18.5 2.2 1.3 2.2 1.3
3G3M1-A4220 22 2.2 1.1 2.2 1.1
Single-phase 200 V
3G3M1-AB001 0.1 8.4 6.7 - -
3G3M1-AB002 0.2 8.4 6.7 - -
3G3M1-AB004 0.4 7.1 4.0 - -
3G3M1-AB007 0.75 6.8 3.5 - -
3G3M1-AB015 1.5 6.8 4.9 - -
3G3M1-AB022 2.2 6.8 4.5 - -
3G3M1-AB037 3.7 5.5 - - -
5-2-3
Slip Compensation
The slip compensation function calculates the torque generated by the motor to infer the slip amount.
As a result of this calculation, the drop in motor rotation speed can be compensated for to suppress
the drop in motor rotation speed. This is useful for improving the speed control accuracy of the motor.
To enable the slip compensation function, select “0: V/f control” or “3: V/f control with speed sensor” at
Drive Control Selection (F42/A14), then set 1 at Slip compensation Function Selection (H442), and set
5 Basic Settings
5-16
M1 Series Standard Type User's Manual (I669)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron M1 Series and is the answer not in the manual?

Omron M1 Series Specifications

General IconGeneral
BrandOmron
ModelM1 Series
CategoryInverter
LanguageEnglish

Related product manuals