When Drive Control Selection (F42) = 15, 16 (synchronous motor)
• The set values of the following parameters are overwritten with the following values according to
the new settings after changing Load Mode Selection (F80).
• Manual Torque Boost V
oltage (F09)
Power supply Model
Capacity
[kW]
Manual Torque Boost Voltage (F09)
Set value
Load Mode Selection (F80)
0: HHD 1: HND 3: HD 4: ND
Three-phase 200 V
3G3M1-A2001 0.1 8.4 6.7 - -
3G3M1-A2002 0.2 8.4 6.7 - -
3G3M1-A2004 0.4 7.1 4.0 - -
3G3M1-A2007 0.75 6.8 3.5 - -
3G3M1-A2015 1.5 6.8 4.9 - -
3G3M1-A2022 2.2 6.8 4.5 - -
3G3M1-A2037 3.7 5.5 4.1 - -
3G3M1-A2055 5.5 4.9 3.4 - -
3G3M1-A2075 7.5 4.4 2.7 - -
3G3M1-A2110 11 3.5 2.1 - -
3G3M1-A2150 15 2.8 1.6 - -
3G3M1-A2185 18.5 2.2 1.3 - -
Three-phase 400 V
3G3M1-A4004 0.4 7.1 4.0 7.1 4.0
3G3M1-A4007 0.75 6.8 3.5 6.8 3.5
3G3M1-A4015 1.5 6.8 4.9 6.8 4.9
3G3M1-A4022 2.2 6.8 4.5 6.8 4.5
3G3M1-A4030 3.0 6.8 4.5 6.8 4.5
3G3M1-A4040 4.0 5.5 4.1 5.5 4.1
3G3M1-A4055 5.5 4.9 3.4 4.9 3.4
3G3M1-A4075 7.5 4.4 2.7 4.4 2.7
3G3M1-A4110 11 3.5 2.1 3.5 2.1
3G3M1-A4150 15 2.8 1.6 2.8 1.6
3G3M1-A4185 18.5 2.2 1.3 2.2 1.3
3G3M1-A4220 22 2.2 1.1 2.2 1.1
Single-phase 200 V
3G3M1-AB001 0.1 8.4 6.7 - -
3G3M1-AB002 0.2 8.4 6.7 - -
3G3M1-AB004 0.4 7.1 4.0 - -
3G3M1-AB007 0.75 6.8 3.5 - -
3G3M1-AB015 1.5 6.8 4.9 - -
3G3M1-AB022 2.2 6.8 4.5 - -
3G3M1-AB037 3.7 5.5 - - -
5-2-3
Slip Compensation
The slip compensation function calculates the torque generated by the motor to infer the slip amount.
As a result of this calculation, the drop in motor rotation speed can be compensated for to suppress
the drop in motor rotation speed. This is useful for improving the speed control accuracy of the motor.
To enable the slip compensation function, select “0: V/f control” or “3: V/f control with speed sensor” at
Drive Control Selection (F42/A14), then set 1 at Slip compensation Function Selection (H442), and set
5 Basic Settings
5-16
M1 Series Standard Type User's Manual (I669)