Stopping via input to a multifunction input terminal
When the HLD terminal is turned ON during acceleration, acceleration is stopped, and when it is
turned OFF, acceleration is resumed.
When the HLD terminal is turned ON during deceleration, deceleration is stopped, and when it is
turned OFF
, deceleration is resumed.
HLD terminal
Output
frequency
T
ime
5-6-4
2-step Acceleration/Deceleration Function
Use the 2-step acceleration/deceleration function to control two acceleration/deceleration time.
The acceleration/deceleration time switching method can be selected from the following four.
E125/E126 = 0: Switching by 2CH terminal (Input T
erminal Function Selection set to “159: 2CH
(2-step acceleration/deceleration)”) (Example 1)
E125/E126 = 1: Switching by 2-step acceleration/deceleration (E127 to E130) (switching fre-
quency set at E127 to E130) (Example 2)
E125/E126 = 2: Switching at forward/reverse switching (Example 3)
E125/E126 = 3: Switching by RT1, RT2 terminals (Example 4)
To switch via an input terminal, allocate “159: 2CH (2-step acceleration/deceleration),” or “4: RT1 (2-
step acceleration/deceleration),” “5: RT2 (Acceleration/deceleration Time Selection 2)” to one of In-
put Terminal [DI1] Function Selection to Input Terminal [DI7] Function Selection (E01 to E05, E98,
E99).
For acceleration time 2 (E12/E14) and deceleration time 2 (E13/E14), set the time from frequency 0
Hz up to the maximum frequency in the same way as acceleration time 1 (F07/E10) and decelera-
tion time 1 (F08/E11).
Acceleration/deceleration pattern and acceleration/deceleration operation stop also can be used.
Parameter
No.
Function name Data
Default da-
ta
Unit
F07 1st Acceleration Time 1
0.00 to 6000 6.00 s
F08 1st Deceleration Time 1
F10
2nd Acceleration Time 1
*1
E11
2nd Deceleration Time 1
*1
E12 1st Acceleration Time 2
E13 1st Deceleration Time 2
E14
2nd Acceleration Time 2
*1
E15
2nd Deceleration Time 2
*1
5 Basic Settings
5-43
M1 Series Standard Type User's Manual (I669)
5-6 Acceleration/deceleration time
5
5-6-4 2-step Acceleration/Deceleration Function