Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit Page
P90
1st PM Motor Overcur-
rent Protection Level
0.00 ; 0.01 to 500.0
0.00 : Disable
0.01 to 500.0 A
50.00 - A
page
6-22
P95
1st PM Motor Magnet-
ic Pole position Offset
0.0 to 359.9°
999: Offset not adjusted
32767
Availa-
ble
deg
page
6-65
4-2-5
Parameter H (High Level Functions)
Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit Page
H03 Data Initialization
0: Disable
1: Initialize all parameters
2: Initialize motor 1 parame-
ters
3: Initialize motor 2 parame-
ters
4: Restore user defined data
5: Initialize all parameters (ex-
cept I/O and communications)
6: Reserved
7: Clear alarm history
8: Clear selection of favorite
function code
0 - -
page
5-4
H04 Retry Count at Trip
0: Disable
1 to 20: Number of retries
0
Availa-
ble
-
page
7-58
H05
Retry Standby Time at
Trip
0.5 to 20.0 s
5
Availa-
ble
s
page
7-58
H06
Cooling Fan Function
Selection
0: Always Fan ON
1: ON/OFF control effective
0
Availa-
ble
-
page
7-99
4 Parameter List
4-116
M1 Series Standard Type User's Manual (I669)