Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit Page
P61
1st PM Motor d-axis
Inductance
0.00 to 500.0mH
4.77 - mH
page
6-65
page
6-22
P62
1st PM Motor q-axis
Inductance
0.00 to 500.0mH
10.70 - mH
page
6-65
page
6-22
P63
1st PM Motor Induced
Voltage Ke
0 to 240 V (200 V class series)
0 to 500 V: (400 V class ser-
ies)
Voltage at rated speed
177 - V
page
6-6
P64
1st PM Motor Iron
Loss
0.0 to 20.0%
100% = Motor rated current
Iron loss at rated speed
5.50
Availa-
ble
%
page
6-6
P65
1st PM Motor d-axis
Inductance Magnetic
Saturation Correction
0.0 to 100.0%
999: Factory default
100.0% = No magnetic satura-
tion
32767
Availa-
ble
%
page
6-6
P74
1st PM Motor Refer-
ence Current at Start-
ing
10 to 200%
100% = Motor rated current
80
Availa-
ble
%
page
6-6
page
6-22
P83 Do not use - - - - -
P84 Do not use - - - - -
P85
1st PM Motor Flux
Limitation V
alue
50.0 to 150.0%
999: Factory default
32767
Availa-
ble
%
page
6-6
P86 Do not use - - - - -
P87
1st PM Motor Refer-
ence Current for Mag-
netic Pole Detection
0 to 200%
Based on the rated current of
the motor
60 - %
page
6-6
P88 Do not use - - - - -
P89 Do not use - - - - -
4 Parameter List
4-115
M1 Series Standard Type User's Manual (I669)
4-2 List of Parameters by Group
4
4-2-4 Parameter P (Motor 1 Parameter)