134
"C" Group: Intelligent Terminal Functions Section 3-7
46 LAC LAD cancellation ON Set ramp times are ignored. Inverter output immedi-
ately follows the freq. command.
OFF Accel. and/or decel. is according to the set ramp
time
47 PCLR Pulse counter clear ON Clear the position deviation data
OFF Maintain the position deviation data
50 ADD ADD frequency enable ON Adds the A145 (add frequency) value to the output
frequency
OFF Does not add the A145 value to the output frequency
51 F-TM Force Terminal Mode ON Force inverter to use input terminals for output fre-
quency and Run command sources
OFF Source of output frequency set by A001 and source
of Run command set by A002 is used
52 ATR Enable torque com-
mand input
ON Torque control command input is enabled
OFF Torque control command input is disabled
53 KHC Clear watt-hour data ON Clear watt-hour data
OFF No action
56 MI1 General purpose input
(1)
ON General purpose input (1) is made ON under EzSQ
OFF General purpose input (1) is made OFF under EzSQ
57 MI2 General purpose input
(2)
ON General purpose input (2) is made ON under EzSQ
OFF General purpose input (2) is made OFF under EzSQ
58 MI3 General purpose input
(3)
ON General purpose input (3) is made ON under EzSQ
OFF General purpose input (3) is made OFF under EzSQ
59 MI4 General purpose input
(4)
ON General purpose input (4) is made ON under EzSQ
OFF General purpose input (4) is made OFF under EzSQ
60 MI5 General purpose input
(5)
ON General purpose input (5) is made ON under EzSQ
OFF General purpose input (5) is made OFF under EzSQ
61 MI6 General purpose input
(6)
ON General purpose input (6) is made ON under EzSQ
OFF General purpose input (6) is made OFF under EzSQ
62 MI7 General purpose input
(7)
ON General purpose input (7) is made ON under EzSQ
OFF General purpose input (7) is made OFF under EzSQ
65 AHD Analog command hold ON Analog command is held
OFF Analog command is not held
66 CP1 Multistage-position
switch (1)
ON Multistage position commands are set according to
the combination of these switches.
OFF
67 CP2 Multistage-position
switch (2)
ON
OFF
68 CP3 Multistage-position
switch (3)
ON
OFF
69 ORL Limit signal of homing ON Limit signal of homing is ON
OFF Limit signal of homing is OFF
70 ORG Trigger signal of homing ON Starts homing operation
OFF No action
73 SPD Speed/position
changeover
ON Speed control mode
OFF Position control mode
77 GS1 * GS1 input ON EN60204-1 related signals: Signal input of "Safe
torque off" function.
OFF
78 GS2 * GS2 input ON
OFF
81 485 Start EzCOM ON Starts EzCOM
OFF No execution
Input Function Summary Table
Option
Code
Terminal
Symbol
Function Name Description

Table of Contents

Other manuals for Omron MX2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MX2 and is the answer not in the manual?

Omron MX2 Specifications

General IconGeneral
BrandOmron
ModelMX2
CategoryInverter
LanguageEnglish

Related product manuals