147
"C" Group: Intelligent Terminal Functions Section 3-7
3-7-11 Other Functions
To avoid the miss-input of the multi-speed due to the time rug, waiting time to
fix the multi-speed can be set by C169. When input is detected, data is fixed
after the time defined with C169.
C148 Logic output 3 operand A All the programmable functions
available for logic (discrete) out-
puts except LOG1 to LOG3, OPO,
no
8 00 –
C149 Logic output 3 operand B 8 00 –
C150 Logic output 3 operator Applies a logic function to calcu-
late [LOG] output state,
Three options:
00... [LOG] = A AND B
01... [LOG] = A OR B
02... [LOG] = A XOR B
8 00 –
"C" Function Run
Mode
Edit
Defaults
Func.
Code
Name Description EU Units
C169 Multistage speed/position
determination time
Set range is 0. to 200. (x 10ms) 8 0. ms
C" Function Run
Mode
Edit
Defaults
Func.
Code
Name Description EU Units