EasyManuals Logo
Home>Omron>Inverter>MX2

Omron MX2 User Manual

Omron MX2
356 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #176 background imageLoading...
Page #176 background image
154
"H" Group: Motor Constants Functions Section 3-8
Permanent Magnet motor
limitations.
When using a Permanent Magnet motor some limitations should be consid-
ered regarding application and functionallity point of view.
From application point of view take this limitations in consideration:
1. Use always on reduced torque applications with a starting torque less than
50%.
2. MX2 in PM mode is not suitable for use in constant torque application
where rapid acceleration/deceleration and low speed operation is need.
Never use for transportation machine and specially for vertical loads such
elevators.
3. Drive is able to control up to 50 times the motor moment of Inertia.
4. Two or more motors could not be driven with one inverter
5. Be careful not exceed the demagnetization current of the motor
From functionality point of view several functions and parameters are not
available when PM mode is selected, next table show which ones.
Function Related Parameters PM mode
2nd control Intelligent input terminalSET08 Non-display
Intelligent output terminalSETM60 Non-display
Torque monitor limit con-
trol
C027, C028 Choices restriction
d009, d010, d012, b040, b045, C054, C059, P033, P034, P036, P041 Non-display
Intelligent input terminal TL(40), TRQ1(41), TRQ2(42), ATR(52) Non-display
Intelligent output terminal OTQ(07), TRQ(10) Non-display
Encoder feedback P003 Choices restriction
d008, d029, d030, H050, H051, P004, P011, P012, P015, P026,
P027, P060, P073, P075, P077
Non-display
Intelligent input terminalPCLR(47), CP1(66), CP3(68), ORL(69),
ORG(70), SPD(73), EB(85)
Non-display
Intelligent outpu terminal DES(22), POK(23) Non-display
Jog A038, A039 Non-display
Intelligent input terminal JG(06) Non-display
IM control A041, A044, A046, A047, b100, b113, H002, H006, H020, H024,
H030, H034
Non-display
V/f gain A045 Non-display
AVR A081, A083, A084 Non-display
Automatic energy-saving
drive
A085, A086 Non-display
Restarting with active
matching frequency
b001, b008, b088, C103 Choices restriction
b028, b030 Non-display
Overcurrent suppression b027 Non-display
Reduced voltage start b036 Non-display
Reverse run protection b046 Non-display
Brake control b120, b127 Non-display
Intelligent input terminal BOK(44) Non-display
Intelligent output terminal BRK(19), BER(20) Non-display
Offline auto-tuning H001 Choices restriction
Dual Rating b049 Non-display
Commercial power source
switching
Intelligent input terminal CS14 Non-display
LAD cancellation Intelligent output terminal LAC46 Non-display

Table of Contents

Other manuals for Omron MX2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MX2 and is the answer not in the manual?

Omron MX2 Specifications

General IconGeneral
BrandOmron
ModelMX2
CategoryInverter
LanguageEnglish