Setting Banks
Setting Banks
The ZFV Series can hold up to eight sets of settings. These settings can be switched
externally when changing the device setup
A set of these settings is called a “bank.”
Switching banks
BANK 1 is selected as the default. BANK 2 and 8 are also available.
MENU mode-[BANK]
Copying banks
Copy the settings of other bank numbers to an already selected bank number.
MENU Mode-[SYS1]-[BANKSET]-[COPY]
Clearing banks
“Clearing” deletes the settings of the currently selected bank number.
MENU Mode-[SYS1]-[BANKSET]-[CLEAR]
Setting the bank switching method
Select how to switch banks.
MENU Mode-[SYS1]-[BANKSET]-[SWITCH]
Setting Description
BANK 1~BANK 8
(default value: BANK 1)
Selects the target bank.
Setting Description
KEY (default value) Banks are switched by the control keys on Amplifier Unit.
I/O Banks are switched by the control keys on Amplifier Unit and input lead sig-
nals.
Switching by input lead signals is enabled only in the RUN mode.
BANKs can also be switched from an external device.
Setting the bank switching method p.60
[SYS1], [SYS2] settings and RUN Mode display settings cannot be cleared.
Header
Overview
Cross-header
Title of each section
Index label
Movement through
menus up to setting
items
Supplementary Explanation
Helpful information regarding operation and reference
pages are introduced here using symbols.
Overview of the
cross-header
Explanation of options
Indicates the section number and title.