90
Section 4 APPENDIX
ZFV
User’s Manual
Section 4
When Gang-mounting Amplifier Units
Rules of gang-mounting
Item Rules
No. of Amplifier Units connectable Maximum 5
No. of mounted sensor heads Up to the number of amplifier units
TRIG signal input Only host device is enabled
TEACH signal input Only host device is enabled
BANK1-3 input Enabled at each amplifier unit
ENABLE output Only host device is enabled
OUTPUT output Depends on the settings (Integrated judgment/Individual judgment)
ERROR output Enabled at each amplifier unit
MENU/ADJ/RUN Only host device is enabled
STD/EXP Enabled at each amplifier unit
All key inputs Enabled at each amplifier unit
TRIG signalENABLE signal
Amplifier unit for inputting fur-
thest right TRIG signal = host
device
Amplifier unit without TRIG signal inputs = client device