15.5Sonartroubleshooting
Scrollingimageisnotbeingdisplayed
P
ossiblecausesPossiblesolutions
Sonardisabled
Enable
PingfromtheSonarapp
’ssoundertab:
Menu>Settings
>Sounder>Ping.
Incorrecttransducerselected
CheckthatthecorrecttransducerisselectedintheSonarapp
’s
Transducertab:
Menu>Settings>T
ransducer>Ping.
Damagedcables
1.Checkthatthetransducercableconnectorisfullyinsertedand
lock
edinposition.
2.Checkthepowersupplycableandconnectorsforsignsof
damageorcorrosion,replaceifnecessary.
3.Withtheunitturnedon,tryflexingthecableneartothedisplay
connectortoseeifthiscausestheunittore-boot/loosepower,
replaceifnecessary.
4.Checkthevessel’sbatteryvoltage,theconditionofthebattery
terminalsandpowersupplycables,ensuringconnectionsare
secure,cleanandfreefromcorrosion,replaceifnecessary.
5.Withtheproductunderload,usingamulti-meter,checkforhigh
voltagedropacrossallconnectors/fusesetc(thiscancausethe
Fishfinderapplicationstostopscrollingortheunittoreset/turn
off),replaceifnecessary.
Damagedorfouled
transducer
Checktheconditionofthetransducerensuringitisnotdamaged
andisfreefromdebris/fouling,cleanorreplaceasnecessary .
W rongtransducerfittedCheckproductandtransducerdocumentationandensurethatthe
transduceriscompatiblewithyoursystem.
Externalsonarmodule:
Sea Talkhs/RayNetnetwork
problem.
•CheckthattheunitiscorrectlyconnectedtotheMFDornetwork
switch.Checkallconnectionsensuringconnectionsaresecure,
cleanandfreefromcorrosion,replaceifnecessary.
Externalsonarmodule:
Softwaremismatchbetween
equipmentmayprevent
communication.
EnsureallR aymarineproductscontainthelatestavailablesoftware,
checktheRaymarinewebsite:www.raymarine.com/softwarefor
softwarecompatibility.
Nodepthreading/lostbottomlock
P ossiblecausesPossiblesolutions
T ransducerlocation
Checkthatthetransducerhasbeeninstalledinaccordancewith
theinstructionsprovidedwiththetransducer.
T ransducerangle
Ifthetransducerangleistoogreatthebeamcanmissthebottom,
adjusttransducerangleandrecheck.
T ransducerkicked-up
Ifthetransducerhasakick-upmechanism,checkthatithasnot
kickedupduetohittinganobject.
P owersourceinsufficient
Withtheproductunderload,usingamulti-meter,checkthe
powersupplyvoltageasclosetotheunitaspossibletoestablish
actualvoltagewhenthecurrentisflowing.(Checkyourproduct’s
Technicalspecificationforpowersupplyrequirements.)
Damagedorfouled
transducer
Checktheconditionofthetransducerensuringitisnotdamaged
andisfreefromdebris/fouling.
T roubleshooting
167