5.1Generalcablingguidance
Cabletypesandlength
Itisimportanttousecablesoftheappropriatetypeandlength
Unlessotherwisestateduseonlystandardcablesofthe
correcttype,suppliedbyRaymarine.
Ensurethatanynon-Raymarinecablesareofthecorrect
qualityandgauge.Forexample,longerpowercablerunsmay
requirelargerwiregaugestominimizevoltagedropalongthe
run.
Routingcables
Cablesmustberoutedcorrectly,tomaximizeperformanceand
prolongcablelife.
DoNOTbendcablesexcessively.Whereverpossible,ensure
aminimumbenddiameterof200mm(8in)/minimumbend
radiusof100mm(4in).
100 mm (4 in)
200 mm (8 in)
Protectallcablesfromphysicaldamageandexposuretoheat.
Usetrunkingorconduitwherepossible.DoNOTruncables
throughbilgesordoorways,orclosetomovingorhotobjects.
Securecablesinplaceusingtie-wrapsorlacingtwine.Coil
anyextracableandtieitoutoftheway.
Whereacablepassesthroughanexposedbulkheador
deckhead,useasuitablewatertightfeed-through.
DoNOTruncablesneartoenginesoruorescentlights.
Alwaysroutedatacablesasfarawayaspossiblefrom:
otherequipmentandcables,
highcurrentcarryingacanddcpowerlines,
antennae.
Strainrelief
Ensureadequatestrainreliefisprovided.Protectconnectors
fromstrainandensuretheywillnotpulloutunderextremesea
conditions.
Cableshielding
Ensurethatthecableisproperlyshieldedthatthecableshielding
isintact(e.g.hasn’tbeenscrapedoffbybeingsqueezedthrough
atightarea).
5.2Cableconnection
Thedisplayhasacombinedpowerandtransducercablethat
isattachedtothetransducer.
00
0
(0.6 )VM
D12 64 2-1
1
2
5
4
3
3
1.Displayrearpanelconnection.
2.Transducerwithcableattached.
3.Drainwire(Thedrainwireisthewirewithasheath).
4.Blackwire(12Vdcnegative).
5.Redwire(12Vdcpositive).
Powerdistribution
Raymarinerecommendsthatallpowerconnectionsaremade
viaadistributionpanel.
Allequipmentmustbepoweredfromabreakerorswitch,with
appropriatecircuitprotection.
Allequipmentshouldbewiredtoindividualbreakersif
possible.
Warning:Powersupplyvoltage
Connectingthisproducttoavoltagesupplygreater
thanthespeciedmaximumratingmaycause
permanentdamagetotheunit.Refertothe
Technicalspecicationsectionforvoltagerating.
Warning:Productgrounding
Beforeapplyingpowertothisproduct,ensureithas
beencorrectlygrounded,inaccordancewiththe
instructionsinthisguide.
GroundingDedicateddrainwire
Thepowercablesuppliedwiththisproductincludesadedicated
shield(drain)wireforconnectiontoavessel'sRFgroundpoint.
ItisimportantthataneffectiveRFgroundisconnectedtothe
system.Asinglegroundpointshouldbeusedforallequipment.
Theunitcanbegroundedbyconnectingtheshield(drain)wire
ofthepowercabletothevessel'sRFgroundpoint.Onvessels
withoutanRFgroundsystemtheshield(drain)wireshouldbe
connecteddirectlytothenegativebatteryterminal.
Thedcpowersystemshouldbeeither:
Negativegrounded,withthenegativebatteryterminal
connectedtothevessel'sground.
Floating,withneitherbatteryterminalconnectedtothe
vessel'sground
Warning:Positivegroundsystems
Donotconnectthisunittoasystemwhichhas
positivegrounding.
32
Dragony/Dragony7

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raymarine Dragonfly and is the answer not in the manual?

Raymarine Dragonfly Specifications

General IconGeneral
BrandRaymarine
ModelDragonfly
CategoryGPS
LanguageEnglish

Related product manuals