Chapter 5 To Trigger the Oscilloscope RIGOL
MSO1000Z/DS1000Z User’s Guide 5-25
Delay Trigger (Option)
In delay trigger, you need to set signal source A and signal source B. The oscilloscope
triggers when the time difference (T) between the specified edges of source A
(Edge A) and source B (Edge B) meets the preset time limit, as shown in the figure
below.
Note: Edge A and Edge B must be neighbouring edges.
T
Source A
Source B
Edge A=
Edge B=
Figure 5-10 Delay Trigger
Trigger Type:
Press Type to open the trigger type list. Rotate to select Delayand press down
. At this point, the trigger setting information is displayed at the upper right corner
of the screen.
For example,
. The trigger type is delay trigger; the current
trigger source is CH1; the trigger level is 0.00 V.
Source A:
Press SourceA to select CH1-CH4 as the trigger source of signal source A.
Edge A:
Press EdgeA to select the trigger edge type of signal source A in delay trigger. It can
be set to the rising edge or falling edge.
Source B:
Press SourceB to select CH1-CH4 as the trigger source of signal source B.
Edge B:
Press EdgeB to select the trigger edge type of signal source B in delay trigger. It can
be set to the rising edge or falling edge.
Delay Type:
Press DelayType to set the time limit condition of delay trigger.

Table of Contents

Other manuals for Rigol MSO1000Z series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol MSO1000Z series and is the answer not in the manual?

Rigol MSO1000Z series Specifications

General IconGeneral
BrandRigol
ModelMSO1000Z series
CategoryTest Equipment
LanguageEnglish

Related product manuals