2.4 Mounting SIMODRIVE POSMO A
2-52
E Siemens AG 2013 All Rights Reserved
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
2.4.2 Preparing the cable
Note
We recommend that connector sleeves are used, but these are not
absolutely necessary.
The outer cable diameter should be maintained in order to guarantee
the IP 54/IP64/IP65 degree of protection.
Use only copper cables with a thermal stability of up to at least 60/75
°C for connection and wiring. See Figure 2-13
S 2 x max. 4 mm
2
, with or without shield, flexible conductor (finely–stranded)
S Gland:
PG13.5 (with shield connection) for outdoors ∅ = 6–12 mm
10120
10
not to scale
6 – 12
Load cable
(shield
is not
absolutely
required)
Shield
Fig. 2-18 Preparing Cable for the load power supply
S 2 x 0.35 mm
2
, with shield
S Gland:
PG13.5 (with shield connection) for outdoors ∅ = 6–12 mm
5100
8
not to scale
6 – 12
PROFIBUS
cable
(without
electronics
power supply)
Shield
Fig. 2-19 Preparing the PROFIBUS cable
Cable for the load
power supply
Cable for
PROFIBUS
(without
electronics
power supply)