Second encoder on the drive
The
configuration of a second encoder on the drive is useful when the second encoder value
is also to be used for this drive (e.g. motor or machine encoder). Note that only a maximum of
two encoder values can be transferred via PROFIdrive message frames.
In principle, the second encoder value can be freely used (e.g. for acquisition of an external
master value), however the use of an encoder as a separate drive object (drive object
DO encoder) is preferable because of the clear functional separation.
Figure 7-53 Configuration of a second encoder on the drive
Encoder as drive object
The
configuration of an encoder as drive object (drive object DO encoder) has the advantage
that this encoder can be used independently of a configured drive (e.g. for acquisition of a
master value).
The configuration is performed by inserting an encoder via the project navigator.
Figure 7-54 Configuration of an encoder as drive object
Note
In
the same way as for axes, a "DO encoder" can also be symbolically interconnected to a "TO
externalEncoder".
Commissioning (software)
7.10 Linking an additional encoder (optional)
SIMOTION D4x5-2
276 Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D4x5-2 and is the answer not in the manual?

Siemens SIMOTION D4x5-2 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D4x5-2
CategoryControl Unit
LanguageEnglish

Related product manuals