4.8 Connecting PROFINET IO components
4.8.1
Wiring PROFINET
Procedure
As standard, a SIMOTION D4x5-2 DP/PN has a PROFINET IO interface with three ports.
The SIMOTION D4x5-2 DP/PN control units can be expanded by an additional PROFINET IO
interface with four ports. For this purpose, a CBE30-2 must be inserted in the option slot of the
control unit.
Suitable PROFINET cables and connectors must be used for the PROFINET connection. The
autocrossing functionality of the PROFINET interfaces means crossed as well as uncrossed
cables can be used.
2QERDUG
352),1(7,2
LQWHUIDFH
;SRUWV33
6HFRQG
352),1(7,2
LQWHUIDFH
&%(;
SRUWV33
Figure 4-15 Connecting PROFINET IO
Connecting
4.8 Connecting PROFINET IO components
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B 85