7.8 Activating the infeed (line module)
Requirement
Before
a drive can be traversed, the infeed (line module) must be switched on and the "Closed-
loop control operation" signal of the infeed must be present at the drives.
If this is not taken into account, this can result in a fault state, and in the worst case, damage
to the infeed.
How the infeed is controlled and how the drives receive the Ready signal depends on the type
of infeed used.
A distinction is made between:
Infeeds without DRIVE‑CLiQ connection
Infeeds with DRIVE‑CLiQ connection
7.8.1 Infeed without DRIVE-CLiQ connection
The infeed is controlled via terminals on the line module, e.g. DO Ready (DC link is precharged
and ´pulse enable is set).
These terminals must be connected to the SIMOTION D4x5‑2 (e.g. wire "DO Ready of the
infeed" to "X122, DI 0 of the D4x5‑2").
The enable signal is queried when the drive is configured and must be interconnected
accordingly.
Commissioning (software)
7.8 Activating the infeed (line module)
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B 267

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D4x5-2 and is the answer not in the manual?

Siemens SIMOTION D4x5-2 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D4x5-2
CategoryControl Unit
LanguageEnglish

Related product manuals