4. Because of the automatic follow-up configuration in the SINAMICS Integrated drive, you
must now execute "Load CPU / drive unit to PG".
5.
Save the project.
Note
When
upgrading SINAMICS drive units (e.g. SINAMICS Integrated) only the p parameters
(setting parameters) are loaded into the upgraded project. The r parameters (monitoring
parameters) are not loaded. The r parameters in the drive unit are derived or calculated
from an automatic subsequent parameterization and must therefore be uploaded to the
project. To do this, execute "Load CPU/drive unit to PG". If the upload is not performed,
this can lead to inconsistencies in the drive parameterization dialog boxes.
8.4.5.5 General information on SINAMICS firmware update
Requirements for firmware update
For a firmware update of the SINAMICS Integrated incl. connected CX32‑2, it is enough to
plug a CF card with new drive firmware into SIMOTION D4x5‑2.
To
ensure that a firmware update of all connected SINAMICS components is performed (Line
and Motor Modules, TM, SMC, …), the CF card must additionally contain a project, incl.
configured drive component, and the drive components must be topologically correctly
connected.
Impermissible operating actions during firmware update
The following actions must be avoided while a firmware update is in progress because they
could cause the firmware update to be interrupted:
Disconnection of the DRIVE-CLiQ cable to the CX32‑2
Connection of an CX32‑2 to DRIVE-CLiQ
POWER ON on D4x5‑2 or CX32‑2 Controller Extensions
Operation of the RESET button on D4x5‑2 or CX32‑2 Controller Extensions
Memory reset with the hardware mode switch
Updates via the SIMOTION IT web server
CPU download and memory reset via HW Config
If a firmware update is interrupted, it may be necessary switch the power off and then on the
power again, and repeat the firmware update.
The following operating actions are not possible during a firmware update:
Going online to the SINAMICS
Delete user data on card
Project download
Download CPU / drive unit to target device
Service and maintenance
8.4 Performing a firmware and project update
SIMOTION D4x5-2
370 Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D4x5-2 and is the answer not in the manual?

Siemens SIMOTION D4x5-2 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D4x5-2
CategoryControl Unit
LanguageEnglish

Related product manuals