You can find diagnostic data and non-volatile SIMOTION data on the CF card in the following
directory:
\USER\SIMOTION\HMI\SYSLOG\DIAG
Additional references
You will find detailed information in the
SIMOTION IT Diagnostics and Configuration
Diagnostics Manual.
9.2.6 Storing diagnostics data and trace on the CF card
As of V4.5, the following data can be saved to the CF card with the
_saveTraceAndDiagnosticFiles system function:
Diagnostics data (same data as when the DIAG button is actuated)
TO trace
Device trace
The function can be used, for example, to collect diagnostic information (e.g. in the event of a
fault) locally on the machine and without backing up SCOUT. The function saves the available
data in a ZIP file, whereby the file name and the archive directory can be specified.
The packed data can be accessed, for example, via the web server.
Diagnostics
9.2 Diagnostic data and non-volatile SIMOTION data
SIMOTION D4x5-2
408 Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D4x5-2 and is the answer not in the manual?

Siemens SIMOTION D4x5-2 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D4x5-2
CategoryControl Unit
LanguageEnglish

Related product manuals