A.2.1 Acceptance test STO (basic functions)
2))
6SHHG
*UHHQ2Q
'LDJQRVWLFV
672GHVHOHFWHG
672DFWLYH
672VHOHFWHG
672VHOHFWLRQ
2Q<HOORZ2Q)ODVKLQJVORZO\
&RQWURO
212))
21672VHOHFWHG
6$)(
5'<
W
W
U
U
U
/('
352),VDIH
U672B$%
U)',
W
S
Figure A-1 Acceptance test for STO (basic functions)
Procedure
To perform an acceptance test of the STO function as part of the basic functions, proceed as
follows:
Status
1. The inverter is ready
The inverter signals neither faults nor alarms of the safety functions (r0945[0…7],
r2122[0…7]).
STO is not active (r9773.1 = 0).
2. Switch on motor
2.1. Enter a speed setpoint ≠ 0.
2.2. Switch on the motor (ON command).
2.3. Check that the correct motor is running.

Appendix
A.2 Examples of acceptance tests
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD 383