4.10.6 This is how you remove the front panel
Removing the front plate of the S120 Combi
To electrically connect additional components, the front cover of the S120 Combi must be
removed.
DANGER
Danger to life through electric shock
A hazardous voltage is still present for up to 5 minutes after the power supply has been
switched off.
Remove the front plate only after 5 minutes have passed.
Procedure:
1. Use a Torx T20 or slotted 1.2 x 6 screwdriver as tool.
2. Remove the two Torx-slotted screws at the front.
Service cases - hardware
4.10 SINAMICS S120 Combi
Software and hardware
Service Manual, 08/2018, 6FC5397-5DP40-6BA1 145