4.19.2 DMC20 connections
Connections
3URWHFWLYHFRQGXFWRU
FRQQHFWLRQ01P
6KLHOGVXSSRUW
;
;
;
5'<
;
;
;
;
X500 ... X505 DRIVE-CLiQ interfaces
X524 Electronics power supply
Figure 4-66 Connections DMC20
4.19.3 This is how you remove a DMC20
Removing
Precondition: The control cabinet is in a no-voltage condition, all of the connectors and cables
are labeled.
Procedure:
1. Before withdrawing it, label the connector X524 for the electronics power supply.
2. Withdraw the connected DRIVE-CLiQ cables X500 – X505 and write the slot designation
on the cable.
3. Release the protective conductor connection and write the position designation on the
cable.
Service cases - hardware
4.19 Hub Modules
Software and hardware
Service Manual, 08/2018, 6FC5397-5DP40-6BA1 229