Page #29 background image
Figure 6-2 Shield of the signal cable connected to EMC shield terminal
&DEOHJODQG
6VKLHOGVXSSRUWHOHPHQW
-XQFWLRQER[
6LJQDOFDEOH
(OHFWURQLF:HLJKLQJ6\VWHP
/RDGFHOO
3$/
%ODFN
*UD\
5HG
%OXH
*UHHQ
:KLWH
SIGNAL-
EXC-
SENSE-
SHIELD
EXC+
SENSE+
SIGNAL+
SIGNAL+
SENSE+
EXC+
SIGNAL-
SENSE-
EXC-
Figure 6-3 Shield of the signal cable connected to shield terminal
The following jumpers are set by default:
Jumper From terminal To terminal
1 EXC- SENSE-
2 EXC+ SENSE+
Note
If the jumpers are missing, the electronic weighing system reports a wire break.
Connecting
6.2 Connection of analog load cells
SIWAREX WP321
Operating Instructions, 08/2019, A5E33715669A-AD 29