EasyManuals Logo
Home>Sony>Monitor>TRINITRON BVM-D9H5U

Sony TRINITRON BVM-D9H5U User Manual

Sony TRINITRON BVM-D9H5U
166 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #38 background imageLoading...
Page #38 background image
1-32
BVM-D9H1U/D9H5U/D9H1E/D9H5E/D9H1A/D9H5A
58
(E)
Chapter 3 Appendix
A1
AA2
B
C(1/2)
C(2/2)
B1(1/2)
B2
B3
B21
C1
C2
B1(2/2)
MAIN MENU
Set by automatic adjustment (using the
color bar signal)
Set input signal data for each channel.
:Current channel is indicated.
:Select the input signal type.
:Select the slot number.
:Select the input connector number.
:Select the slot when the external sync signal is used.
:Select the audio input number (BVM-D9H5 only)
:Select the color temperature.
:Enter the aperture adjustment value.
:Give the channel name. (Select in the “C2” menu)
Set the preset value with the
adjustment knobs.
D (next page)
:Select the level of
YP
BPR signals.
:Current channel is indicated.
:Select the number of active scanning lines per frame.
:Set the holizontal picture position.
:Set the 4:3 marker position.
:Set the 4:3 marker width.
:Set the NTSC setup level when the BKM-127W is installed.
:Select the matrix when YP
B
PR signals of the signal formats
480/60I or 480/60P are input.
:Select ON to compensate for a distorted picture when the input
signals from the VCR are not typical. (Effective only when the
signal formats 480/60I or 575/50I are input.)
You can copy the color temperature
data.
Menu Configuration


CONTROL PRESET ADJ...
MENU
COLOR TEMP ADJ...
INPUT CONFIG... 
REMOTE...
SYSTEM CONFIG... 
STATUS...
ALIGNMENT... 

p
A
B
C
D
E
F
G
CHROMA:100CONTRAST:100
PHASE :100BRIGHT :100
 
MANUAL
  


 
 
TO CANCEL :MENU KEY
TO CONFIRM:ENTER KEY



MANU AL...
 
CONTROL PRESET ADJ
AUTO...
 



 
 


p


 
AUTO
FULL FIELD WHITE 100%
8COLOR BAR 100% 
8COLOR BAR 75% 
 
SMPTE OLOR BAR 
EIA COLOR BAR 


C
p


STD   
COLOR TEMP ADJ
MANUAL 
PROBE...
COPY...
 
 



p
TS D   
ADJUST
 
RED:CONTRAST KNOB
GREEN :BRIGHT KNOB
BLUE :CHROMA KNOB
LUMINANCE :PHASE KNOB
TO CANCEL :MENU KEY
TO CONFIRM :ENTER KEY

AIN  
:0500 G:0500 R:0500
G
B
TS D   
ADJUST
 


 
 
 


IAS  
:0500 G:0500 R:0500
B
B


STD   
PROBE
START 
PROBEBKM-14L
X0.313
Y 0.329
LOWLIG T ( 20IRE) 2.7
HIGHLIGHT(100IRE) 120
LOADREFVALUE...

H
p


STD   
COPY FROM
STD 
COL1
COL2
 
D65 
D93


p


 
REF VALUE
D65 
D93

 
 



p
HC 1  
FORMAT 
YPBPRSMPTE
RGB
NTSC,PAL 
D1-SDI 
HD-SDI



p
HC 1  
CHANNEL NAME
PROG
EDIT
CAM
VTR 

NEW NAME 


p
HC 1  
INPUT CONFIG(1/2)
FORMAT... YPBPR
SLOTNOSLOT1
INPUTNO1
EXT SY NC SLOT SLOT1
AUDIO INPUT 1
COLOR TEMP STD
APERTURE VALUE 100
CHANNEL NAME... PROG
p
HC 1  
INPUT CONFIG(2/2)
1125/60I SYSTEM 1080I
HPHASE000
MARKER PHASE 000
MARKER WIDTH  000
NTSC SETUP 7.5
YPBPR MATRIX 60I
VCR MODE OFF

p
Select the probe for color temperature adjustment.
:Select the probe (BKM-14L, SLS 9400, CA-100, TF6,
or PM 5639)
:Confirm/Change x, y value on the Chromaticity
Coordinate and luminance
59
(E)
Chapter 3 Appendix
D
F/F1
F2
G
E1
E2
E3
E4
E5
D1
D2
E(1/2)
E(2/2)
D21 D211(1/2) D211(2/2)
E11
F3
:Data about the installed
optional board is displayed.
:Select the display mode of the signal format and display position.
:Select the display mode of the channel number and display position.
:Select the display mode of the channel name and display position.
:Select the caption display mode.
:For qualified service personnel
:Select the power-up condition.
:Select the power-up input channel.
:Set the time between power-up and the
beginning of degaussing.
:Select the CONT/BRT settings in the
COLOR TEMP ADJ.
:Set the short-cut function to the F2 key.
:Set the automatic color control.
You can copy the INPUT
CONFIG menu and SYSTEM
CONFIG menu (except
DEGAUSS DELAY) from the
monitor which you assign the
address No.
MAIN MENU
Use for adjusting the position, size
and geometry of the picture.


CONTROL PRESET ADJ...
MENU
COLOR TEMP ADJ...
INPUT CONFIG... 
REMOTE...
SYSTEM CONFIG... 
STATUS...
ALIGNMENT... 

p
A
B
C
D
E
F
G
ES RIAL REMOTE
REMOTE 
MONITOR ADDRESS 001
GROUP ADDRESS 001

 
ARALLEL REMOTE OFF
ARALLEL REMOTE CONFIG.


p
P
P
 
REMOTE CONFIG
1PIN...CH1
2PIN...CH2
3PIN...TALLYRED
4PIN...TALLY GREEN
5PIN...EXTSYNC
6PIN...UNDERSCAN
7PIN...16:9
8PIN...4:3MARKER
p
  
PIN...
CH 01
----
UNDER SCAN 
16:9 
H DELAY
VDELAY
EXT SYNC 
APERTURE 
p
M ONO  
B LUE ONLY
1
  
PIN...
R OFF 
G OFF
B OFF
4:3 MARKER 
CAPTION VISION
TALLY RED
TALLY GREEN 
DEGAUSS
p
P OWERO FF 
 
1
  
YSTEM CONFIG(1/2)
STANDBY MODE OFF
DEFAULTCH...LAST
DEGUSS DELAY 000
CONT/BRT HOLD OFF
COL TEMP SHORT-CUT OFF
ACC SWON
CONFIG COPY...

p
S
  
YSTEM CONFIG(2/2)
FORMAT DISPLAY AUTO
POSITION BOTTOM LEFT
CHNOAUTO
POSIT ION TOP RIGHT
CH AMEAUTO
POSITION TOP LEFT
CAPTIONOFF
MAINTENANCE...
p
S
N


  
COPY FROM
MONITOR ADDRESS 001


 
 



p
9 1 1 YPBPR 

H SL IN FORMAT NAME
STATUS (1/ 2)
1 1  1 YPBPR PROG
2 2 1 NTSC PAL 
3 3 2 D1-SDI 
4 1 1 YPBPR 
5 2 NTSC,PAL 
6 2 1 NTSC,PAL 
7 1 1 YPBPR 
8 3 1 D1-SDI 
2
C


 
STATUS (2/2)
ODEL NAME  BVM-D9H5U
ERIALNO2001234
PERATION TIME 000123H
OFTWARE VERSI N 1.00
 
SLOT1 COMPONENT 
SLOT2 NTSC,PAL 
SLOT3 D1-SDI 
O
M
S
O
S
p


 
LOT1 COMPONENT
ODEL NAME   BKM-129X
ERIALNO9071501

 
 



S
M
S


 
ALIGNMENT
VSIZE   00
V CENTER 00
HSIZE00
HPHASE 00
HPIN 00
HKEY00


p

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sony TRINITRON BVM-D9H5U and is the answer not in the manual?

Sony TRINITRON BVM-D9H5U Specifications

General IconGeneral
BrandSony
ModelTRINITRON BVM-D9H5U
CategoryMonitor
LanguageEnglish

Related product manuals