1F-8 Engine Cooling System:
Installation
Install radiator reservoir tank in the reverse order of
removal. Pay attention to the following points:
• Apply THREAD LOCK to the reservoir tank mounting
bolts and tighten them.
NOTE
Fit the clamp to bolt (1).
: Thread lock cement 99000–32110
(THREAD LOCK CEMENT SUPER 1322 or
equivalent)
• Fill the reservoir tank to the upper level “A”. Refer to
“Cooling System Inspection in Section 0B (Page 0B-
14)”.
Cooling Fan Inspection
B817H21606009
Cooling fan operating temperature
Standard
(ON→OFF): Approx. 105 °C (221 °F)
(OFF→ON): Approx. 100 °C (212 °F)
Inspect the cooling fan in the following procedures:
1) Disconnect the cooling fan motor coupler (1).
2) Test the cooling fan motor for load current with an
ammeter connected as shown in the figure.
If the fan motor does not turn, replace the cooling fan
assembly with a new one. Refer to “Radiator /
Cooling Fan Motor Removal and Installation
(Page 1F-5)”.
NOTE
• When making this test, it is not necessary
to remove the cooling fan.
• Make sure that the battery has a capacity
enough to supply the motor with 12 V.
• With the motor running at full speed, the
ammeter should indicate an amperage not
higher than 5 A.
3) Connect the cooling fan motor coupler.
Cooling Fan Relay Inspection
B817H21606010
Inspect the fan relay in the following procedures:
1) Remove the seat. Refer to “Exterior Parts Removal
and Installation (GSF650/S/A/SAK7) in Section 9D
(Page 9D-6)”.
2) Remove the cooling fan relay (1).
“A”: Upper level
“A”
1
I717H1160018-01
1
I717H1160016-01
2. Fan motor 3. Ammeter 4. Battery
2
3
4
I718H1160048-01
1
I718H1160005-01