Charging System: 1J-13
Specifications
Service Data
B817H21A07001
Battery
CAUTION
!
Never use anything except the specified battery.
Generator
Tightening Torque Specifications
B817H21A07002
NOTE
The specified tightening torque is also described in the following.
“Regulator / Rectifier Construction (Page 1J-8)”
Reference:
For the tightening torque of fastener not specified in this section, refer to “Tightening Torque List in Section 0C
(Page 0C-7)”.
Special Tools and Equipment
Recommended Service Material
B817H21A08001
Item Specification Note
Type designation YTX9-BS
Capacity 12 V, 28.8 kC (8 Ah)/10HR
Standard electrolyte S.G. 1.320 at 20 °C (68 °F)
Item Specification Note
Generator coil resistance 0.2 – 0.8 Ω
Generator maximum output Approx. 400 W at 5 000 r/min
Generator no-load voltage
(When engine is cold)
60 V (AC) and more at 5 000 r/min
Regulated voltage 14.0 – 15.5 V at 5 000 r/min
Fastening part
Tightening torque
Note
N⋅mkgf-mlbf-ft
Generator stator set bolt 11 1.1 8.0 )(Page 1J-6)
CKP sensor mounting bolt 11 1.1 8.0 )(Page 1J-6)
Generator rotor bolt 120 12.0 87.0 )(Page 1J-6)
Material SUZUKI recommended product or Specification Note
Sealant SUZUKI BOND No.1207B or
equivalent
P/No.: 99000–31140 )(Page 1J-6)