2-52
CONTROLS
LOAD SAFETY DEVICE
The load safety devices include an
emergency shut-off valve and an overload
warning device. The emergency shut-off
valve prevents the boom or arm from falling.
The overload warning device sounds an
alarm when an excessive load is detected.
Emergency shut-off valve
The emergency shut-off valve prevents the
boom or arm from falling rapidly.
Warning
If the emergency shut-off valve is
activated and the boom or arm falls,
immediately move away from the load
being lifted and go to a safe location.
Boom
Arm (option)
If the emergency shut-off valve (1) or (2) is
activated, immediately set the operating
levers to the neutral position. Do not move
the operating lever to the boom or arm
lowering side. Ask your sales or service
dealer for repair.
If the engine can be started without
problems, the boom or arm can be lowered
with the operating lever. Slowly lower the
boom or arm while ensuring safety.
Procedure 1 (when engine can be started)
Perform this operation within 10 minutes
after the engine stopping.
1. Sit at the operator’s seat.
2. Turn the starter switch to the ON position.
3.Lower
thesafetylocklevertotheunlock
position
4. Slowly push the operating lever forward to
lower the boom.
ACCESSORIES
2-Piece boom
Second boom