Command groups
Table 2-41: Vertical commands (cont.)
Command
Description
CH<x>:PRObe:SET Sets or queries aspects of probe accessory user interfaces, for example probe
attenuation factors.
CH<x>:PRObe:UNIts? Returns the units of the probe that is attached to the specied channel.
CH<x>:PROBECal?
Returns the probe calibration status.
CH<x>:PROBECOntrol Sets or queries the probe range.
CH<x>:PROBEFunc:EXTAtten Sets the attenuation value for the specied channel to the specied scale factor.
Or queries the user-specied attenuation.
CH<x>:PROBEFunc:EXTDBatten Sets the attenuation value for the specied channel to the specied value in
decibels.
Or queries the user-specied attenuation in decibels.
CH<x>:PROBEFunc:EXTUnits Sets or queries the alternate unit for the external attenuator of the specied
channel.
CH<x>:PROBEFunc:EXTUnits:STATE Sets or queries the custom units enable state for the speci ed channel.
CH<x>:SCAle Sets or returns the vertical scale for the specied analog channel.
CH<x>:TERmination Sets channel input termination.
CONFIGuration:ANALOg:BANDWidth? Queries the maximum licensed bandwidth of the instrument.
REF:ADDNew
Adds the specied reference. Argument is of the form "REF<NR1> ", where
NR1 1.
REF:DELete
Deletes the specied reference.
REF:REF<x>:DESKew Sets or queries the deskew time for the specied reference.
REF:REF<x>:LABel:COLor Sets or queries the color of the specied ref label.
REF:REF<x>:LABel:FONT:BOLD Sets or queries the bold state of the specied reference label.
REF:REF<x>:LABel:FONT:ITALic Sets or queries the italic state of the specied reference label.
REF:REF<x>:LABel:FONT:SIZE Sets or queries the font size of the specied reference label.
REF:REF<x>:LABel:FONT:TYPE Sets or queries the font type of the specied reference label.
REF:REF<x>:LABel:FONT:UNDERline Sets or queries the underline state of the specied reference label.
REF:REF<x>:LABel:NAMe
Sets or queries the label of the designated waveform.
REF:REF<x>:LABel:XPOS Sets or queries the position of the reference waveform label on the X axis.
REF:REF<x>:LABel:YPOS Sets or queries the position of the reference waveform label on the Y axis.
REF:LIST? Lists all currently dened references.
REF:REF<x>:SOUrce Sets or queries the lename used by the given reference.
VERTical:DESKew:FROM:
CUSTOMPROPAgation
Sets or queries a target (FROM) delay that you can specify when the
propagation delay of the target (FROM) probe used for deskew cannot be
detected automatically.
VERTical:DESKEW:STATIC Sets or queries the target channel for performing channel-to-channel deskew
adjustment.
VERTical:DESKew:TO:CUSTOMPROPAgation Sets or queries a target (TO) delay that can be specied by the user when
the propagation delay of the target (TO) probe used for deskew cannot be
detected automatically.
2-86 MSO54, MSO56, MSO58, MSO58LP Programmer

Table of Contents

Other manuals for Tektronix MSO54

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MSO54 and is the answer not in the manual?

Tektronix MSO54 Specifications

General IconGeneral
BrandTektronix
ModelMSO54
CategoryTest Equipment
LanguageEnglish

Related product manuals