Commands listed in alphabetical order
Conditions
Requires optio
n SR-AERO.
Group
Bus
Syntax
BUS:B<x>:MIL1553B:LOWTHRE SHold <NR3>
Related Commands
BUS:B<x>:MIL1553B:SOUrce
Arguments
<NR3> is the MIL-STD-1553 lower threshold for the specified bus.
Examples
BUS:B3:MIL1553B:LOWTHRESH OLD -200e-3 sets the Bus 3 MIL-STD-1553
lower threshold to -200 mV.
BUS:B2:MIL1553B:LOWTHRESH OLD? might return
:BUS:B2:MIL1553B:LOWTHRES HOLD -500.0000E-3 indicating the Bus 2
MIL-STD-1553 lower threshold is set to -500 mV.
BUS:B<x>:MIL1553B:POLarity
This command sets or queries the source polarity for the specified MIL-STD-1553
bus. The bus is specified by x.
Conditions
Requires option SR-AERO.
Group
Bus
Syntax
BUS:B<x>:MIL1553B:POLarit y {NORMal|INVERTed}
BUS:B<x>:MIL1553B:POLarit y?
Arguments
NORMal specifies normal polarity.
INVE
RTed
specifies inverted polarity.
Examples
BUS:B3:MIL1553B:POLARITY INVERTED sets Bus 3 MIL-STD-1553 polarity
to inverted.
BUS:B2:MIL1553B:POLARITY? might return :BUS:B2:MIL1553 B:POLARITY
NORMAL
, indicating that the Bus 2 MIL-STD-1553 polarity is set to normal.