Commands listed in alphabetical order
BUS:B3:PARALL
EL:CLOCKSOUrce:THRESHOLD?
might return
:BUS:B3:PARALLEL:CLOCKSOU rce:THRESHOLD 750.00000E-3 indicates the
threshold of the clock source of parallel Bus 3 is currently set to 750.0 mV.
BUS:B<x>:RS
232C:BITRate
This command sets or queries the RS-232C bit rate for bus<x>,
where the bus number is specified by <x>. If you select Custom, use
BUS:B<x>:
RS232C:BITRate:CUSTom tosetthebitrate.
Conditions
Requires option SR-COMP.
Group
Bus
Syntax
BUS:B<x>:RS232C:BITRate {CUSTOM|RATE30 0|RATE1K|RATE2K |
RATE9K|RATE19K|RATE38K|RA TE115K|RATE921K}
BUS:B<x>:RS232C:BITRate?
Arguments
Arguments are the available bit rates.
Examples
BUS:B1:RS232C:BITRATE RATE9K sets the bit rate for the RS-232C bus B1 to
9000 bits-per-second.
BUS:B1:RS232C:BITRATE? might return :BUS :B1:RS232C:BITRATE 9000,
indicating that the bit rate for the RS-232C bus B1 is set to 9000 bits-per-second.
BUS:B<x>:RS232C:BITRate:CUSTom
This command sets or queries the RS-232C custom bit rate for the specified bus.
The bus is specified by x.
Conditions
Requires option SR-COMP.
Group
Bus
Syntax
BUS:B<x>:RS232C:BITRate:C USTom <NR1>
BUS:B<x>:RS232C:BITRate:C USTom?
Related Commands
BUS:B<x>:RS232C:BITRate
2-164 MSO54, MSO56, MSO58, MSO58LP Programmer