Commands listed in alphabetical order
Table 2-44: DATa and WFMOutpre Parameter Settings (cont.)
WFMOutpre Settings
DATa:EN Cd g Setting :ENCdg :BN_Fmt :BYT_Or :BYT_NR
SRPbinary
BIN RP
LSB
1,2,8
SFPbinary
BIN FP
LSB
4
Examples
DATA:ENCDG RPBinary sets the data encoding format to be a positive integer
where the most significant byte is transferred first.
DATA:ENCDG? might return :DATa:ENCDG SRPB INARY for the format of the
outgoing w aveform data .
DATa:SOUrce
This command sets or queries the location of waveform data that is transferred
from the instrument by the CURVe?Query.
Group
Waveform Transfer
Syntax
DATa:SOUrce <wfm>[<,><wfm>]
DATa:SOUrce?
Related Commands
CURVe, DATa
Arguments
<wfm> is the location of the waveform data that will be transferred from the
instrument to the c ontroller. It can consist of CH<x>, MATH<x>, REF<x>,
DIGITALALL. Note that digital d ata is transferred as 16-bit data, with the
least-significant bit representing D0, and the most-significant bit representing D15.
<wfm> can consist of the following:
CH<x> selects the specified analog channel as the source.
MATH<x> selects the specified reference waveform as the source. The reference
number is specified by x, which ranges from 1 through 4.
REF<x> selects the specified reference waveform as the source. The reference
number is specified by x, which ranges from 1 through 8.
CH<x>_D<x> selects the specified digital channel.
CH<x>_DAll selects the specified supper channel group of digital channels.
DIGITALALL selects digital waveforms as the source. The Digital data is
transferred as 16-bit data, with the least-significant bit representing D0, and the
MSO54, MSO56, MSO58, MSO58LP Programmer 2-217