H9 ASD Installation and Operation Manual 171
Pattern 1 Repeat
Program Pattern Run Pattern Run
This parameter sets the number of times to repeat the Pattern Group 1.
Settings:
1 = Once Then Stop
2 – 254 = Number of Repeats
255 = Infinite (Forever)
Direct Access Number — F522
Parameter Type — Numerical
Factory Default 255 (Infinite)
Changeable During Run — No
Minimum — 1
Maximum — 255 (Infinite)
Units — Repetitions
F522 F522