3-76 BA 50Z3/6003 en – Edition 4.3 * * 5003b330.fm
Operation
Protective Front Guard structure category II (option)
Danger!
Danger of piercing/penetration by objects from the front!
Causes severe injury or death.
☞ Install a protective Front Guard structure in areas with danger from the
front, for example pipes, tree trunks etc.
☞ Machine operation is prohibited without a protective Front Guard structure.
Notice!
The protective Front Guard structure corresponds to category II according to ISO
10262:1998.
• The operator must ensure that the danger situation is evaluated and that the
national regulations are observed.
• The operator must ensure that only work is performed that does not require any
higher protection.
• Accidents cannot be fully avoided despite equipping a machine with protective
structures.
1 Stop and park the machine. Stop the engine.
2 A minimum 2 persons are required for installing/removing.
3 Mounting point A (upper).
Fig. 158: Protective Front Guard structure (symbolic repre-
sentation)
Fig. 159: Upper mounting point
A