BA 50Z3/6003 en – Edition 4.3 * 5003b520.fm 5-15
Maintenance
5.8 Replacing the filter element of the air conditioning system (option)
Caution!
The filter elements will be damaged if they are washed or brushed out.
☞ Never reuse damaged filter elements.
☞ Ensure cleanliness when replacing the filter elements.
Caution!
Clean the filter elements only with compressed air, bearing in mind the
following:
☞ Wear safety glasses and protective clothing.
☞ Carefully clean the filter with compressed air.
☞ Do not aim the compressed air at the skin or at other people.
☞ Do not use compressed air for cleaning your clothing.
If equipped with optional air conditioning, the machine is fitted with a filter element located under
the seat.
Replace the filter element every 500 service hours by a new one.
Notice!
Tilt the cab to replace the filter element.
– see chapter 3.41 Raising/lowering the cab on page 3-65
☞ Stop the engine.
☞ Remove the ignition key and carry it with you.
☞ Raise the control lever base.
☞ Raise the cab and secure it.
☞ Slacken the screws and the L-shaped bracket A of filter element B and remove the
bracket.
☞ Remove filter element B.
☞ Install the new filter element B.
☞ Install the L-shaped bracket A of the filter element again with the screws.
☞ Lower the cab again and secure it.
Fig. 269: Replacing the filter element
A
B