5.1
Document Handler
RAP
This RAP
is
used for document handler
faults that do not indicate
a
status code.
One problem
is
that the document
is
not
sensed
by
the Document Handler.
Q
The circuit diagram is on the
next page.
Initial Actions
Ensure that the document
is
in
good condition.
Ensure that the Document
Handler
is
properly grounded
(PL
5.1).
Refer to Normal Call for Anti
Static cleaning procedures.
Procedure
Enter the code [Top Right Segment] to
check the Front document sensor.
NOTE: The bottom Copy Output lamp
(2510)
or the
right
Copy Media
lamp
(251
5)
is
lit
on the Control
Panel when the sensor
is
blocked.
Actuate the Front Document Sensor
(Q1).
The
Copy Output lamp
(2510)
or
the right Copy Media lamp
(2515)
goes
on then off when the sensor is actuated.
Go to FLAG
1
and check the wiring
for a short circuit.
If
there
is
no short
circuit to frame, replace the Front
Document Sensor
(Q1).
If the
problem persists replace the
Controller
PWB
(A3).
Proceed to wrap up the call.
/
CONTROL
PWB
I
CONTROL
PWB
5.9
Document
Handb*
PRP

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xerox 2515 and is the answer not in the manual?

Xerox 2515 Specifications

General IconGeneral
BrandXerox
Model2515
CategoryCopier
LanguageEnglish

Related product manuals