Print Engine Theory of Operation
Phaser® 6120 Color Laser Printer Service Manual
7-38
Image Transfer Belt Unit
Waste toner scraped off by the Cleaning Blade is collected by the Toner Collecting Screw
for Transfer Belt.
The waste toner collected by the Toner Collecting Screw is conveyed to the Imaging Unit
by way of the Waste Toner Conveyance Unit.
.
Waste Toner Full Detection System
A waste toner near full condition is detected using the output state of the Waste Toner Near
Full Detection Board (PWB-C).
A waste toner near full condition is detected by letting the light emitted from the LED
mounted on the Waste Toner Near Full Detection Board (PWB-C) travel through the light
guide.
4139to2085e0
Toner Collecting Screw
Toner Agitating Screw

Table of Contents

Other manuals for Xerox Phaser 6120

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xerox Phaser 6120 and is the answer not in the manual?

Xerox Phaser 6120 Specifications

General IconGeneral
ColorYes
Print technologyLaser
Time to first page (black, normal)13 s
Time to first page (color, normal)22 s
Print speed (black, normal quality, A4/US Letter)20 ppm
Print speed (color, normal quality, A4/US Letter)5 ppm
Internal memory128 MB
Processor model300 MHz, 32 bit RISC
Maximum print size210 x 297 mm
Maximum ISO A-series paper sizeA4
I/O portsUSB
Power requirements200 – 240 VAC / 100 – 127 VAC 50/60 Hz
Networking featuresEthernet/Fast-Ethernet
Non-operating relative humidity (non-condensing)10 - 85 %
Total input capacity200 sheets
Maximum input capacity500 sheets
Printer fontsPostScript
Maximum duty cycle35000 pages per month
Number of PostScript fonts139
Power consumption (printing)380 W
Storage temperature (T-T)-20 - 40 °C
Operating temperature (T-T)10 - 32 °C
Operating relative humidity (H-H)10 - 80 %
Weight and Dimensions IconWeight and Dimensions
Dimensions (WxDxH)442 x 395 x 341 mm

Related product manuals