Error Messages and Codes 3-185
Finisher Away From Printer
The Inverter Docking (Joint) Switch indicates that the Finisher is detached from the
printer.
Initial Actions:
■ Cycle the printer's power.
■ If the problem persists follow the procedure below.
Troubleshooting Reference Table
Applicable Parts Wiring and Plug/Jack References
■ Inverter Docking Sensor
■ Inverter Control Board
■ Options Map 9 Inverter Sensor Locator
■ Options Inverter Sensors diagram
Troubleshooting Procedure Table
Step Actions and Questions Yes No
1
Check the following for evidence of fault,
damage, obstruction, or debris:
■ Inverter Docking Sensor
■ Finisher Base
Are there any defects or misalignment?
Replace any
damaged parts.
Go to Step 2.
2
Test the Inverter Joint Sensor
Run the Service Diagnostics Inverter Joint
Sensor test.
Does the switch function correctly?
Replace the Engine
Control Board
(
page 8-112).
Go to Step 3.
3
Check the Inverter Docking Sensor signal.
Disconnect SNSCN1 from the Inverter
Control Board.
Does the voltage change between 0 and
5vdc on connector SNSCN1-2 when the
sensor is actuated?
Replace the Inverter
Control Board.
Replace the
sensor. If the error
persists, replace
the harness.