4-16 Phaser 7400 Color Printer Service Manual
Power Supply
LVPS Overcurrent Protection Circuit
This circuit stops all outputs if the 24 VDC, 5 VDC or 3.3 VDC power supply detect a
short circuit. The circuit is reset when the short is removed, the power is turned off,
and then on again.
LVPS Overvoltage Protection Circuit
This circuit stops all outputs if the 24 VDC, 5 VDC or 3.3 VDC power supply
exceeds the specified voltage. The operating point is 32 VDC or more for 24 VDC,
7
VDC or more for 5 VDC, or 6 VDC or more for 3.3 VDC.
+24 VDC Output Stopped By Interlock Switch
Opening the Top Cover, Door A or Front Door opens the Interlock Switch. This shuts
off the +24 VDC supplied to the motors, clutches, and solenoids.
AC Power Supply Troubleshooting
Troubleshooting Reference Table
Applicable Parts Wiring and Plug/Jack References
■ LVPS, PL3.1.4 ■ Print Engine LVPS (page 10-39)
Troubleshooting Procedure Table
Step Action and Questions Yes No
1
Check the voltage at the AC wall outlet.
Is there approximately 110 VAC (or 220 VAC if
the printer is a 220 V configuration) at the AC wall
outlet?
Go to Step 2. Notify the
customer of
improper AC
output from the
outlet.
2
Check the power cord for defects or a loose
connection.
Replace or
reseat the power
cord.
Replace the
LVPS
(
page 8-121).