V5 series inverter
37
4
4
4
4 Function
Function
Function
Function Parameters
Parameters
Parameters
Parameters
4-1.
4-1.
4-1.
4-1. Function
Function
Function
Function parameter
parameter
parameter
parameter table
table
table
table
Parameters can be changed while running
×
Parameters can not be changed while running
*
Parameters can only be read, user can not changed
1
1
1
1
.
.
.
.
Basic
Basic
Basic
Basic running
running
running
running parameters
parameters
parameters
parameters (
(
(
( G
G
G
G roup
roup
roup
roup P0)
P0)
P0)
P0)
Group
Group
Group
Group P0
P0
P0
P0 Basic
Basic
Basic
Basic running
running
running
running parameters
parameters
parameters
parameters
Parameter
Parameter
Parameter
Parameter
Name
Name
Name
Name
Setting
Setting
Setting
Setting Range
Range
Range
Range
Minmum
Minmum
Minmum
Minmum
unit
unit
unit
unit
Factory
Factory
Factory
Factory setting
setting
setting
setting
Change
Change
Change
Change
P0.00
Control mode
selection
0 V/F control
1 : open-loop vector control
1
0
×
P0.01
Frequency setting
mode
0 Analog potentiometer in the
panel
1 Increase / Decrease key
2
digit setting 1
via keys on th e
panel
3 digit setting 2 via terminal
UP/DOWN
4 digit setting 3 via serial port
5 VI analog input VI-GND
6 CI analog input CI-GND
7 Pulse input PULSE
8 Combined setting mode refe r
to P3.00
1
0
P0.02
Running frequency
in digit mode
P0.19
High frequency limit P0.20 low
frequency limit
0.01HZ
50.00HZ
P0.03
Running command
selection
0 Running frequency via
operation panel control
1 Teminal control
2 serial port control
1
0
P0.04
Running direction
setting
Unit
s place
0 jog forward via panel
1 jog reverse via panel
Ten
s place
0 permit reverse
1 prohibit reverse
1
00
P0.05
Run forward/reverse
dead time
0.0 120.0s
0.1s
0.1s
P0.06
Highest ouput
frequency
50.00Hz 500.00Hz
0.01Hz
50.00Hz
×
P0.07
Basic running
frequency
1.00Hz 500.00Hz
0.01Hz
50.00Hz
×
P0.08
Highest output
voltage
1 480V
1V
Inverter rated
voltage
×
P0.09
Torque boost
0.0 %~ 30.0
0.1
2.0
P0.10
Cut-off frequency
for torque boost
0.00Hz basic running
frequency P0.07
0.00
25.00Hz
P0.11
Torque boost mode
0 manual
1 automatical
1
0
P0.12
Carrier frequency
1.0K 14.0K
0.1K
8.0K
×
P0.13
Acc/Dec direction se
0 linear Acc/Dec
1
0
×

Table of Contents