EasyManuals Logo
Home>Xinje>DC Drives>VB5-41P5

Xinje VB5-41P5 User Manual

Xinje VB5-41P5
107 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #56 background imageLoading...
Page #56 background image
V5 series inverter
50
11
11
11
11 .
.
.
. Vector
Vector
Vector
Vector control
control
control
control parameters
parameters
parameters
parameters
Group
Group
Group
Group PA
PA
PA
PA
1 Manual mode
Ten
s place of LED Amplitude control
0 Variable amplitude
1 Fixed amplitude
P9.02
Pre-traverse frequecncy
0.00 500.00Hz
0.01Hz
0.00Hz
P9.03
Waiting time before pre-
traverse frequency
0.0 3600.0s
0.1s
0.0s
P9.04
Traverse operating amplitude
0.0 50.0
0.1
0.0
P9.05
Jitter frequency
0.0 50.0
with reference to P9.04
0.1
0.0
P9.06
Traverse operating cycle
0.1 999.9s
0.1s
10.0s
P9.07
Rising time of trangle wave
0.0 98.0
with
0.1
50.0
P9.08
Reference length
0.000 65.535(km)
0.001km
0.000km
P9.09
Actual length
0.0 65.535km
Saving at power off
0.001km
0.000km
P9.10
Times of length
0.001 30.000
0.001
1.000
P9.11
correction coefficient of
length
0.001 1.000
0.001
1.000
P9.12
Perimeter of shaft
0.01 100.00cm
0.01cm
10.00cm
P9.13
Number of pulses per
revolution
1 9999
1
1
Group
Group
Group
Group PA
PA
PA
PA Vector
Vector
Vector
Vector Control
Control
Control
Control Parameters
Parameters
Parameters
Parameters
Parameter
Parameter
Parameter
Parameter
Name
Name
Name
Name
Range
Range
Range
Range
Minmum
Minmum
Minmum
Minmum
unit
unit
unit
unit
Factory
Factory
Factory
Factory setting
setting
setting
setting
Change
Change
Change
Change
PA.00
Motor auto-tu n e
0 No tu n e
1 auto tune
1
0
×
PA.01
R ated voltage of motor
0 400V
1
Dependent on
inverter
s model
×
PA.02
R ated current of motor
0.01 500.00A
0.01A
Dependent on
inverter
s model
×
PA.03
R ated frequency of motor
1 99Hz
1Hz
Dependent on
inverter
s model
×
PA.04
Rated rot ated speed of motor
1 9999 r/min
1r/min
Dependent on
inverter
s model
×
PA.05
Polarity of motor
2 48
1
Dependent on
inverter
s model
×
PA.06
Stator inducta nce of motor
0.1 5000.0mH
0.1mH
Dependent on
inverter
s model
×
PA.07
Rotor inductance of motor
0.1 5000.0mH
0.1mH
Dependent on
inverter
s model
×
PA.08
Exciting induction of motor
0.1 5000.0mH
0.1mH
Dependent on
inverter
s model
×

Table of Contents