P3.42 control s that if b-25 ~ b-40 can be displayed in parameter group
by
four figures. The parameter values are in hex
which should be changed to binary ones according to the sequency of monitor parameters when using.The relationship
between four figures and parameters are shown in Fig. 4-17.
Fig.
Fig.
Fig.
Fig. 4
4
4
4 - 17
17
17
17 Display
Display
Display
Display parameters
parameters
parameters
parameters selection
selection
selection
selection 2
2
2
2
(
(
(
( R
R
R
R efer
efer
efer
efer to
to
to
to P73
P73
P73
P73 for
for
for
for b-09
b-09
b-09
b-09 ~
~
~
~ b-40
b-40
b-40
b-40 )
)
)
)
Note:
Note:
Note:
Note: A:
A:
A:
A: Thousand
Thousand
Thousand
Thousand
’
’
’
’
s
s
s
s place,
place,
place,
place, B:
B:
B:
B: Hundred
Hundred
Hundred
Hundred
’
’
’
’
s
s
s
s place,
place,
place,
place,
C:
C:
C:
C: Ten
Ten
Ten
Ten
’
’
’
’
s
s
s
s place,
place,
place,
place, D:
D:
D:
D: Unit
Unit
Unit
Unit
’
’
’
’
s
s
s
s place
place
place
place
Ten
’
s place
,
unit
’
s place : used to set stop status
Thousand
’
s place, hundred
’
s place : used to set running status
Example: When you want to let the inverter display current value in running status and display DC injucetion bus voltage
value, you can se t P3.43=0304
.
You
can also press the key to view other monitor parameters .
P3.44 : It is used to set proportion value between display value and output frequency of monitor param eter b-14.
Display
Display
Display
Display value
value
value
value of
of
of
of b
b
b
b -
-
-
- 14
14
14
14 =
=
=
= Output
Output
Output
Output frequency
frequency
frequency
frequency of
of
of
of inverter
inverter
inverter
inverter × P3.44
P3.44
P3.44
P3.44
P3.45 is used to select the usage of JOG/REV key in the panel , the references are shown below:
0 : select to JOG
1 : select to REV
4-2-5
4-2-5
4-2-5
4-2-5
.
.
.
.
Function
Function
Function
Function parameters
parameters
parameters
parameters of
of
of
of terminal
terminal
terminal
terminal ( Group
Group
Group
Group P4
P4
P4
P4 )
Multi-function input terminals X1~X8 support various functions which you can select freely to satisfy your
requirement
.
You
can define the function of X1 ~ X8 by setting the value of P4.00 ~ P4.07
,
refer to Table 4 - 1 for
details, Among these terminals, X7 corresponds to FWD and X8 corresponds to REV .
Table
Table
Table
Table
4-1
4-1
4-1
4-1 Multi-function
Multi-function
Multi-function
Multi-function selection
selection
selection
selection