Mechanical Installation
2
2.2 Installation Environment
YASKAWA SIEPC71061753C GA500 Technical Manual 31
2.2 Installation Environment
The installation environment is important for the lifespan of the product and to make sure that the drive
performance is correct. Make sure that the installation environment aligns with these specifications.
Refer to Conditions on page 48 for information about the installation of finless-type drives.
Environment
Conditions
Area of Use
Indoors
Power Supply
Overvoltage Category III (IEC60664)
Surrounding Air
Temperature
IP20/UL Open Type: -10 °C to +50 °C (14 °F to 122 °F)
IP20/UL Type 1: -10 °C to +40 °C (14 °F to 104 °F)
When you install the drive in an enclosure, use a cooling fan or air conditioner to keep the internal air temperature in the permitted range.
Do not let the drive freeze.
Humidity
95%RH or less
Do not let condensation form on the drive.
Storage Temperature
-20 °C to +70 °C (-4 °F to +158 °F) (short-term temperature during transportation)
Surrounding Area
Pollution degree 2 or less (IEC 60664-1)
Install the drive in an area without:
Oil mist, corrosive or flammable gas, or dust
Metal powder, oil, water, or other unwanted materials
Radioactive or flammable materials.
Harmful gas or fluids
Salt
Direct sunlight
Keep wood and other flammable materials away from the drive.
Altitude
1000 m (3281 ft) Maximum
Note:
Derate the output current by 1% for each 100 m (328 ft) to install the drive in altitudes between 1000 m to 4000 m (3281 ft to 13123 ft).
It is not necessary to derate the rated voltage in these conditions:
Installing the drive at 2000 m (6562 ft) or lower
Installing the drive between 2000 m to 4000 m (6562 ft to 13123 ft) and grounding the neutral point on the power supply.
Contact Yaskawa or your nearest sales representative if you will not ground the neutral point.
Vibration
10 Hz to 20 Hz: 1 G (9.8 m/s
2
, 32.15 ft/s
2
)
20 Hz to 55 Hz: 0.6 G (5.9 m/s
2
, 19.36 ft/s
2
)
Installation Orientation
Install the drive vertically or horizontally for sufficient airflow to cool the drive.
Refer to the drive Technical Manual for more information.
NOTICE: Do not put drive peripheral devices, transformers, or other electronics near the drive. Shield the drive from electrical
interference if components must be near the drive. Components near the drive can cause incorrect drive operation from
electrical interference.
NOTICE: Do not let unwanted objects, for example metal shavings or wire clippings, fall into the drive during drive installation.
Put a temporary cover over the drive during installation. Remove the temporary cover before start-up. Unwanted objects inside
of the drive can cause damage to the drive.

Table of Contents

Other manuals for YASKAWA CIPR-GA50CB001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA CIPR-GA50CB001 and is the answer not in the manual?

YASKAWA CIPR-GA50CB001 Specifications

General IconGeneral
BrandYASKAWA
ModelCIPR-GA50CB001
CategoryController
LanguageEnglish

Related product manuals