6 Wiring
6.1.2 Typical Main Circuit Wiring Examples
6-4
6.1.2 Typical Main Circuit Wiring Examples
(1) Three-phase 200 V, 22 kW and 30 kW SERVOPACKs
L1/R
L1C/r
PG
SGDM-ADB
U
V
W
M
ALM-
+24V
0 V
24
1Ry
ALM+
31
32
1D
OFF
1MC
1Ry
ON
1SA
1Ry
L2/S
L3/T
L3C/t
B1
B2
DU
DV
DW
U(A)
V(B)
W(C)
1
1b
U
V
W
FG
FG
CN1
CN2
R ST
1PL
SGDH-AEB
SERVOPACK
(Alarm lamp)
Regen-
erative
Resistor
DB Unit
Fan
Main circuit
power
Thermal
protector
Three-phase
200 to 230 VAC
(50/60 Hz)
+10
-15
%
: Lamp for display
: Surge absorber
: Flywheel diode
1PL
1SA
1D
1QF
FIL
1KM
1Ry
: Circuit breaker (for inverters)
: Noise filter
: Contactor
: Relay
1KM
1KM
1QF
FIL
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Other manuals for YASKAWA E-II Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA E-II Series and is the answer not in the manual?

YASKAWA E-II Series Specifications

General IconGeneral
BrandYASKAWA
ModelE-II Series
CategoryServo Drives
LanguageEnglish

Related product manuals