10 Inspection, Maintenance, and Troubleshooting
10.1.2 Warning Display
10-4
10.1.2 Warning Display
The relation between warning displays and warning code outputs is shown in table 10.2.
Note: Warning code is not output without setting Pn001 = n.1 (Outputs both Alarm Codes and
Warning Codes.)
Table 10.2 Warning Displays and Outputs
Warning
Display
Warning Name Meaning
Warning Code Output
ALO1 ALO2 ALO3
A.90
Excessive Position Error
Warning
The position errors exceed the setting in Pn51E.
HHH
A.91
Overload This warning occurs before the overload alarms (A.71 or
A.72) occur. If the warning is ignored and operation con-
tinues, an overload alarm may occur.
LHH
A.92
Regenerative Overload This warning occurs before the regenerative overload
alarm (A.32) occurs. If the warning is ignored and opera-
tion continues, a regenerative overload alarm may occur.
HLH
A.93
Absolute Encoder Battery
Voltage Lowered
This warning occurs when the absolute encoder battery
voltage is lowered. If the warning is ignored and operation
continues, an overload alarm may occur.
LLH
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Other manuals for YASKAWA E-II Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA E-II Series and is the answer not in the manual?

YASKAWA E-II Series Specifications

General IconGeneral
BrandYASKAWA
ModelE-II Series
CategoryServo Drives
LanguageEnglish

Related product manuals