Chapter 3 Structure and Principles
Confidential and Proprietary Information of ZTE CORPORATION 41
the power part must be designed in hot backup mode, and two
power supply modes of -48V DC and 220V AC are designed.
Load sharing is adopted for the master/slave power supply
module working in normal state. When a power supply becomes
faulty, the other module will supply the system with the power
for normal operation.
Figure 29 shows the power supply of
ZXR10 GER.
FIGURE 29 ZXR10 GER POWER SUPPLY
Power module 1#
Power module 2#
Switching backplane
System main
control module 1#
System main
control module 2#
Service
interface card
Power supply module is divided according to the GER models.
These are described below.
Topic Page No
ZXR10 GER02/04 Power Supply 41
ZXR10 GER08 Power Supply 43
ZXR10 GER02/04 Power Supply
GPWA panel is shown in Figure 30.
FIGURE 30 PANEL VIEW OF THE GPWA
GPWA technical parameters are given below:
Technical Parameters
Input voltage: mono-phase 110/220VAC±10%
Input current: (110V)3.0A/(220V)1.5A
Frequency: 65/50±5%
Maximum power consumption (W): 300W
Load Sharing
GPWA