ACH580 E-Clipse bypass and packaged drive user manual 241
Technical data
460 Volt fuses for packaged drive
575 Volt fuses for packaged drive
480 Volt
Nominal Output
Range
Base
Drive
Frame
Size
Internal Drive
Fuse Rating
External Fuse for
Disconnect Option
Type Code
1
Drive
Current
Package
Power
A HP Class
Current
Rating
Class
Max Current
Rating
ACH580-PxR-02A1-4 2.1 1 R1 Class CC 15A N/A N/A
ACH580-PxR-03A0-4 3 1.5 R1 Class CC 15A N/A N/A
ACH580-PxR-03A5-4 3.5 2 R1 Class CC 15A N/A N/A
ACH580-PxR-04A8-4 4.8 3 R1 Class CC 15A N/A N/A
ACH580-PxR-07A6-4 7.6 5 R1 Class CC 15A N/A N/A
ACH580-PxR-012A-4 12 7.5 R1 Class CC 15A N/A N/A
ACH580-PxR-014A-4 14 10 R2 Class CC 30A N/A N/A
ACH580-PxR-023A-4 23 15 R2 Class CC 30A N/A N/A
ACH580-PxR-027A-4 27 20 R3 Class T 40A N/A N/A
ACH580-PxR-034A-4 34 25 R3 Class T 60A N/A N/A
ACH580-PxR-044A-4 44 30 R3 Class T 60A N/A N/A
ACH580-PxR-052A-4 52 40 R4 Class T 80A N/A N/A
ACH580-PxR-065A-4 65 50 R4 Class T 90A N/A N/A
ACH580-PxR-077A-4 77 60 R4 Class T 100A N/A N/A
ACH580-PxR-096A-4 96 75 R5 Class T 150A N/A N/A
ACH580-PxR-124A-4 124 100 R6 Class T 200A N/A N/A
ACH580-PxR-156A-4 156 125 R7 Class T 225A N/A N/A
ACH580-PxR-180A-4 180 150 R7 Class T 300A N/A N/A
ACH580-PxR-240A-4 240 200 R8 Class T 350A
Class J
or RK1
400A Max
1) “PxR” represents both PCR and PDR.
575 Volt
Nominal Output
Range
Base
Drive
Frame
Size
Internal Drive
Fuse Rating
External Fuse for
Disconnect Option
Type Code
1, 2
Drive
Current
Package
Power
A HP Class
Current
Rating
Class
Max Current
Rating
ACH580-PxR-02A7-6 2.7 2 R2 Class CC 15A N/A N/A
ACH580-PxR-03A9-6 3.9 3 R2 Class CC 15A N/A N/A
ACH580-PxR-06A1-6 3.5 6.1 R2 Class CC 15A N/A N/A
ACH580-PxR-09A0-6 4.8 9 R2 Class CC 15A N/A N/A
ACH580-PxR-011A-6 7.6 11 R2 Class CC 30A N/A N/A
ACH580-PxR-017A-6 17 15 R2 Class CC 30A N/A N/A
ACH580-PxR-022A-6 22 20 R3 Class T 40A N/A N/A
ACH580-PxR-027A-6 27 25 R3 Class T 40A N/A N/A
ACH580-PxR-032A-6 32 30 R3 Class T 40A N/A N/A
ACH580-PxR-041A-6 41 40 R5 Class T 50A N/A N/A