EasyManuals Logo

ABB ACS150 series User Manual

ABB ACS150 series
173 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #143 background imageLoading...
Page #143 background image
Technical data
142
Losses, cooling data and noise
Losses and cooling data
Frame size R0 has natural convection cooling. Frame sizes R1…R2 are provided
with an internal fan. The air flow direction is from bottom to top.
The table below specifies the heat dissipation in the main circuit at nominal load and
in the control circuit with minimum load (I/O not in use) and maximum load (all digital
inputs in the on state and the fan in use). The total heat dissipation is the sum of the
heat dissipation in the main and control circuits.
T
y
p
e
ACS150-
x =
E/U
Heat
dissip
a
tion
Air flow
Main circuit
Control circuit
Rated I
1N
and
I
2N
Min
Max
W
BTU/Hr
W
BTU/Hr
W
BTU/Hr
m
3
/h
ft
3
/min
1-phase U
N
= 200…240 V (200, 208, 220, 230, 240 V)
01x-02A4-2
25
85
6
.3
22
12.3
42
-
-
01x-04A7-2
46
157
9.6
33
16.0
55
24
14
01x-06A7-2
71
242
9.6
33
16.0
55
24
14
01x-07A5-2
73
249
10.6
36
17.1
58
21
12
01x-09A8-2
96
328
10.6
36
17.1
58
21
12
3-phase U
N
= 200…240 V (200, 208, 220, 230, 240 V)
03x-02A4-2
19
65
6
.3
22
12.3
42
-
-
03x-03A5-2
31
106
6.3
22
12.3
42
-
-
03x-04A7-2
38
130
9.6
33
16.0
55
24
14
03x-06A7-2
60
205
9.6
33
16.0
55
24
14
03x-07A5-2
62
212
9.6
33
16.0
55
21
12
03x-09A8-2
83
283
10.6
36
17.1
58
21
12
3-phase U
N
= 380…480 V (380, 400, 415, 440, 460, 480 V)
03x-01A2-4
11
38
6
.7
23
13.3
45
-
-
03x-01A9-4
16
55
6
.7
23
13.3
45
-
-
03x-02A4-4
21
72
10.0
34
17.6
60
13
8
03x-03A3-4
31
106
10.0
34
17.6
60
13
8
03x-04A1-4
40
137
10.0
34
17.6
60
13
8
03x-05A6-4
61
208
10.0
34
17.6
60
19
11
03x-07A3-4
74
253
14.3
49
21.5
73
24
14
03x-08A8-4
94
321
14.3
49
21.5
73
24
14
00353783.xls
J
Noise
Frame size
Noise level
dBA
R0
<35
R1
52...55
R2
<62
00353783.xls
J

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACS150 series and is the answer not in the manual?

ABB ACS150 series Specifications

General IconGeneral
Power Range0.37 to 4 kW
Frequency Range0 to 500 Hz
Protection ClassIP20
Overload Capacity150% for 60 seconds
Braking ChopperBuilt-in
Control MethodScalar control
Supply Voltage200-240 V (1-phase), 200-480 V (3-phase)
EMC FilterBuilt-in
Input Voltage200-240 V (1-phase), 200-480 V (3-phase)
Protection FeaturesOvervoltage, undervoltage, overcurrent, short-circuit
Communication OptionsModbus RTU
Voltage Range200 to 240 V (1-phase), 380 to 480 V (3-phase)