412 Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
Appendix E Motor Control Feature Support
Enable the Current Limiting Feature
In this example, a Message Configuration (MSG) instruction is configured to
set the CurrentLimitingEnable attribute for axis 3 of a dual-axis inverter. The
Instance field is used to direct the message to the proper axis. For single-axis
inverters the value of 1 is used for Instance.
Set the CurrentVectorLimit Attribute Value
For current limiting, the CurrentVectorLimit attribute is used to help
determine the OperativeCurrentLimit of the drive. Set the
CurrentVectorLimit value to artificially lower OperativeCurrentLimit below
the drive or motor peak current limits.
1. Select the Parameter List category and scroll to CurrentVectorLimit.
2. Set the CurrentVectorLimit value appropriate for your application.
IMPORTANT The CurrentVectorLimit attribute appears in the Parameter List of the Logix
Designer application, version 29.00 and later. If you are using a previous
version, the CurrentVectorLimit attribute must be set via a Message
Configuration (MSG) instruction.

Table of Contents

Other manuals for Allen-Bradley Kinetix 5700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley Kinetix 5700 and is the answer not in the manual?

Allen-Bradley Kinetix 5700 Specifications

General IconGeneral
BrandAllen-Bradley
ModelKinetix 5700
CategoryServo Drives
LanguageEnglish

Related product manuals