EasyManuals Logo
Home>Allen-Bradley>Controller>Micro830

Allen-Bradley Micro830 User Manual

Allen-Bradley Micro830
354 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #178 background imageLoading...
Page #178 background image
164 Rockwell Automation Publication 2080-UM002K-EN-E - March 2019
Chapter 8 Use the High-Speed Counter and Programmable Limit Switch
HSC Interrupt POU
This is the name of the Program Organizational Unit (POU) which is executed
immediately when this HSC Interrupt occurs. You can choose any
pre-programmed POU from the drop-down list.
Auto Start (HSC0.AS)
The Auto Start is configured with the programming device and stored as part of
the user program. The auto start bit defines if the HSC interrupt function
automatically starts whenever the controller enters any run or test mode.
Mask for IV (HSC0.MV)
The MV (Overflow Mask) control bit is used to enable (allow) or disable (not
allow) an overflow interrupt from occurring. If this bit is clear (0), and an
overflow reached condition is detected by the HSC, the HSC user interrupt is
not executed.
This bit is controlled by the user program and retains its value through a power
cycle. It is up to the user program to set and clear this bit.
Mask for IN (HSC0.MN)
The MN (Underflow Mask) control bit is used to enable (allow) or disable (not
allow) a underflow interrupt from occurring. If this bit is clear (0), and a
Underflow Reached condition is detected by the HSC, the HSC user interrupt is
not executed.
This bit is controlled by the user program and retains its value through a power
cycle. It is up to the user program to set and clear this bit.
Description Data Format HSC Modes
(1)
(1) For Mode descriptions, see Count Down (HSCSTS.CountDownFlag) on page 151.
User Program Access
AS - Auto Start bit 0…9 read only
Description Data Format HSC Modes
(1)
(1) For Mode descriptions, see Count Down (HSCSTS.CountDownFlag) on page 151..
User Program Access
MV - Overflow Mask bit 0…9 read only
Description Data Format HSC Modes
(1)
(1) For Mode descriptions, see Count Down (HSCSTS.CountDownFlag) on page 151.
User Program Access
MN - Underflow Mask bit 2…9 read only

Table of Contents

Other manuals for Allen-Bradley Micro830

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley Micro830 and is the answer not in the manual?

Allen-Bradley Micro830 Specifications

General IconGeneral
BrandAllen-Bradley
ModelMicro830
CategoryController
LanguageEnglish

Related product manuals